Proliner  
Roofing Cladding Normal Profile Load Tables Proliner 1000/32 (0.5mm)
Profile Proliner 1000/32
The Span Tables below have been created in accordance with EN 1993-1-3 (Eurocode EC3) and calculated by the Steel Construction Institute (SCI). The values are based on a maximum permitted deflection of Span/200 under imposed load.
Load factor (working load to ultimate) 1.5 (in accordance with Eurocode).
Deflection for limit of span L/200

GRAVITY parameters 0.5mm
Bottom flange in compression
Moment capacity (kNm/m) 0.824
Inertia (cm4/m) 7.288
Bottom flange in tension
Moment capacity (kNm/m) 0.699
Inertia (cm4/m) 7.31
 
Shear resistance (kN/m) 19.953
Web crushing mid (kN/m) 4.903
Web crushing end (kN/m) 2.452
 
Inertia gross section (cm4/m) 8.596
 
Proliner 1000/32 - 0.5mm
Span/Load Table - GRAVITY - Working load UDL (kN/m2)
GRAVITY Span in Metres
Span
Type
Design
Case
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2
Single
Moment
3.73 3.08 2.59 2.21 1.90 1.66 1.46 1.29 1.15 1.03 0.93 0.85 0.77
Inertia
6.24 4.69 3.61 2.84 2.27 1.85 1.52 1.27 1.07 0.91 0.78 0.67 0.59
Reaction
3.27 2.97 2.72 2.51 2.34 2.18 2.04 1.92 1.82 1.72 1.63 1.56 1.49
Limiting
3.27 2.97 2.59 2.21 1.90 1.66 1.46 1.27 1.07 0.91 0.78 0.67 0.59

Double
Moment
4.39 3.63 3.05 2.60 2.24 1.95 1.72 1.52 1.36 1.22 1.10 1.00 0.91
Inertia
10.40 7.81 6.02 4.73 3.79 3.08 2.54 2.12 1.78 1.52 1.30 1.12 0.98
Reaction
2.61 2.38 2.18 2.01 1.87 1.74 1.63 1.54 1.45 1.38 1.31 1.25 1.19
Interaction
2.05 1.80 1.59 1.42 1.27 1.15 1.05 0.96 0.88 0.81 0.75 0.69 0.64
Limiting
2.05 1.80 1.59 1.42 1.27 1.15 1.05 0.96 0.88 0.81 0.75 0.69 0.64

Multiple
Moment
5.49 4.54 3.81 3.25 2.80 2.44 2.15 1.90 1.70 1.52 1.37 1.25 1.13
Inertia
10.40 7.81 6.02 4.73 3.79 3.08 2.54 2.12 1.78 1.52 1.30 1.12 0.98
Reaction
2.97 2.70 2.48 2.29 2.12 1.98 1.86 1.75 1.65 1.56 1.49 1.42 1.35
Interaction
2.41 2.12 1.88 1.68 1.51 1.37 1.24 1.14 1.05 0.96 0.89 0.83 0.77
Limiting
2.41
2.12
1.88
1.68
1.51
1.37
1.24
1.14
1.05
0.96
0.89
0.83
0.77
 
Proliner 1000/32 - 0.5mm
Span/Load Table - UPLIFT - Working load UDL (kN/m2)
UPLIFT Span in Metres
Span
Type
Design
Case
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2
Single
Moment
4.39 3.63 3.05 2.60 2.24 1.95 1.72 1.52 1.36 1.22 1.10 1.00 0.91
Inertia
6.23 4.68 3.60 2.84 2.27 1.85 1.52 1.27 1.07 0.91 0.78 0.67 0.58
Reaction
3.27 2.97 2.72 2.51 2.34 2.18 2.04 1.92 1.82 1.72 1.63 1.56 1.49
Limiting
3.27 2.97 2.72 2.51 2.24 1.85 1.52 1.27 1.07 0.91 0.78 0.67 0.58

Double
Moment
3.73 3.08 2.59 2.21 1.90 1.66 1.46 1.29 1.15 1.03 0.93 0.85 0.77
Inertia
10.38 7.80 6.01 4.73 3.78 3.08 2.53 2.11 1.78 1.51 1.30 1.12 0.97
Reaction
2.61 2.38 2.18 2.01 1.87 1.74 1.63 1.54 1.45 1.38 1.31 1.25 1.19
Interaction
1.92 1.68 1.48 1.32 1.18 1.06 0.96 0.88 0.80 0.74 0.68 0.63 0.58
Limiting
1.92 1.68 1.48 1.32 1.18 1.06 0.96 0.88 0.80 0.74 0.68 0.63 0.58

Multiple
Moment
4.66 3.85 3.24 2.76 2.38 2.07 1.82 1.61 1.44 1.29 1.17 1.06 0.96
Inertia
10.38 7.80 6.01 4.73 3.78 3.08 2.53 2.11 1.78 1.51 1.30 1.12 0.97
Reaction
2.97 2.70 2.48 2.29 2.12 1.98 1.86 1.75 1.65 1.56 1.49 1.42 1.35
Interaction
2.27 1.98 1.75 1.56 1.40 1.27 1.15 1.05 0.96 0.88 0.82 0.76 0.70
Limiting
2.27
1.98
1.75
1.56
1.40
1.27
1.15
1.05
0.96
0.88
0.82
0.76
0.70
 
SCI Assessed 'SCI Assessed Quality Mark'. This mark testifies that the Steel Construction Institute (SCI) has independently verified the technical data above.
Figures and Comments given here are given for guidance purposes only. While care has been taken to ensure accuracy Duggan Profiles & Steel Service Centre Ltd. and its related companies do not accept liability for errors / or omissions. Customers should satisfy themselves of the suitability of the products supplied or manufactured by Duggan Profiles & Steel Service Centre Ltd. for the use intended.